What are types

Types of construction, proof of usability and proof of conformity

B.

Plywood
basalt
Construction types of raw ceilings, classification according to DIN 4102-4
Types of construction, proof of usability and proof of conformity
Lumber, labels
Lumber, formats
Building physics (via u-wert.net)
Construction products, proof of usability and proof of conformity
Building regulations list
Building material class according to DIN 4102-1
Component thicknesses according to wu guideline
Components wooden roof structure
Construction contract law in the German Civil Code from 01.01.2018
Method of fastening for bituminous waterproofing membranes
Fastening method for plastic / elastomer sealing sheets
Inspection / higher load screed
Makeshift coverage
Design water level
Rated value of the compressive stress of a flat roof insulation
Bentonite surface waterproofing, three-layer
Bentonite surface waterproofing, single-layer
Bentonite surface waterproofing, two-layer
Planking with plasterboard and plasterboard
Calculated rain donation
Concrete cover
Concrete pavement
Bed elevators
Movement joints in waterproofing
Movement joints in the floor structure
Reinforcement, slack and prestressed
Reinforcement, reinforced concrete
Designation of a sand-lime brick according to DIN V 106
Beaver tail tile
Bishop's cap
Bitumen / polymer bitumen roof waterproofing membrane
Bitumen sheeting
Block construction, multi-layer standing
Block bricks
Blower door test
Floor leveling under precast screeds
Floor coverings on precast screeds
Floor coverings with pole
Floor coverings without a pole
Soil moisture according to DIN 18533-1
Fire barrier, ETICS
Fire detectors (lintel detectors and ceiling detectors) for door locking systems
Fire bar, ETICS
Fire barrier, horizontal
Fire barrier, vertical
Fire behavior, class according to DIN EN 13501-1
Fire behavior, class according to DIN EN 13501-1 for floor coverings
Fuels
Glued laminated timber (glulam)
Glulam, qualities
Cross-laminated timber construction
Board stacking plate
BUS (Binary Unit System)
Bush enclosure
Bus participants

The model building regulations and the state building regulations derived from them stipulate that types of construction may only be used if their usability for the respective purpose has been proven. A distinction is made between the following types:

  • regulated types of construction that do not deviate or do not significantly deviate from the technical rules introduced as technical building regulations and the generally recognized rules of technology, and
  • non-regulated types

When using the following proof of usability and compliance (summary from the sample building regulations, MBO 2002, and the building rules list):

Condition for classification

Certificate of usability

Proof of Conformity

1.The type of construction does not deviate or does not deviate significantly from the technical rules introduced as technical building regulations and the generally recognized rules of technology (regulated design)

no / no significant deviation from the technical rules introduced as technical building regulations and the generally recognized rules of technology

Execution in accordance with the technical rules introduced as technical building regulations and the generally recognized rules of technology

Declaration by the user (the executing company) on the execution of the design in accordance with the technical rules introduced as technical building regulations and the generally recognized rules of technology

2.The type of construction deviates significantly from the technical rules introduced as technical building regulations or there are no generally recognized rules of technology for the type of construction (not regulated type)

The type of construction is contained in the building regulations list A, Part 3

abP

Declaration by the user (the executing company) on the execution of the construction type and on the use of the construction products in accordance with the provisions of the AbP

All non-regulated types

abZ

Declaration by the user (the executing company) on the execution of the construction type and on the use of the construction products in accordance with the provisions of the AbZ

All non-regulated types (in exceptional cases)

ZiE

Declaration by the user (the executing company) on the execution of the design and the use of the construction products in accordance with the provisions of the ZiE

Legend:

abZ: General building approval (issued by the German Institute for Building Technology)

abP: General building inspection test certificate (issued by a recognized certification body)

Goal: Approval in individual cases (issued by the responsible supreme building authority)

The current building regulations list is available on the website of the German Institute for Building Technology (DIBt)> to download provided.

Additional information: ► 402 | System floors, ► 420 | Drywall, ► 433 | Metal false ceilings